TitleProduct

FRP Waste Gas Purification Tower/ Gas Scrubbers

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-27 23:05

  • Browse the number:

    150

Send an inquiries

Company Profile

Beijing ZLRC Environmental Protection Equipment Co., Ltd.

By certification [File Integrity]

Contact:Mr. Yong Zhang(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website: http://cnzlrc.sdshuangyun.com/

PRODUCT DETAILS
ZJP Serious FRP/GRP/Fiberglass purification tower
 

 
Acid gas purification tower series ZJP-X is made of GRP and PVC. The outer surface of the tower adopts water-tolerant and anti-aging gel coat resin with the thickness above 0.5mm. Between the inner and outer surfaces is alkali-free wax-free untwisted wove roving as the anti-aging transition layer. Its resin content is more than 75%. The quantity of the layers meets the technical standard. The resin content is up to 60~70% to ensure the reliability of the tower strength.
 
Structure:
The purification tower is made of a circular tower and flanges by sectional connection. The concrete structure consists of liquid storage tank, air inlet section, two spray sections, cyclone plate, air outlet hood and other components. The characteristics of the purification tower are: convenient production, easy installation and maintenance, high strength, small footprint. Double fillers and sprays are used to make full contact of gas and liquid and to improve the purification efficiency. The tower is equipped with a glass fiber reinforced plastic centrifugal fan and a plastic or stainless steel water pump. When purified air quantity is more than 10,000 cubic meters, two water pumps can meet the design requirement.
 
 
Purification tower body:
 
1. Composite GRP liquid storage tank, dosing tubes, filtrating device on pipette, composite GRP air inlet section.
2. The first, second liquid discharge sections are made of a row of Y-1 shape nylon nozzles, Pall ring filter and PMMA viewing holes.
3. The cyclone plate improves the effect of retaining water.
4. FRP hood cover.
5. F4-72 type FRP centrifugal fan.
6. Plastic or stainless steel centrifugal pump.
7. Other accessories such as plastic pipe valves, fixing bracket, detection ladder, inlet pipe, etc. The user can customize during ordering.
 
Purification tower series ZJP-X components:
outlet hood cover, cyclone plate, filler layer, nozzle, viewing hole, inlet pipe, centrifugal fan, liquid discharge tube, liquid level indicator, liquid storage tank, valve, pipette, centrifugal water pump
 

Overall and installation dimensions Unit: mm
 
Model ZJP-1.5 ZJP-3 ZJP-5 ZJP-7.5 ZJP-10 ZJP-20 ZJP-30 ZJP-40 ZJP-50
Overall dimensions Φ 600 800 1000 1300 1500 2200 2700 3100 3500
Φ1 250 360 400 450 500 700 1000 1120 1250
H 4200 4200 4200 4200 4200 6200 6200 6200 6700
AxB 224x256 280x320 380x320 315x360 315x360 560x640 700x800 840x960 840x960
Installation dimensions Φ2 800 1000 1200 1500 1700 2400 2900 3300 3700
L1 140 140 140 140 140 380 380 380 380
L2 100 100 100 100 100 270 270 270 270
L3 178 178 178 178 178 470 470 470 470
L4 660 760 860 1060 1160 1900 2150 2350 2550
L5 840 900 1100 1300 1400 2100 2500 3000 3000
B 240 288 288 316 316 365 365 365 365
 
Specifications of purification tower
Model ZJP-1.5 ZJP-3 ZJP-5 ZJP-7.5 ZJP-10 ZJP-20 ZJP-30 ZJP-40 ZJP-50
Design air quantity (m³/h) 1500 3000 5000 7500 10000 20000 30000 40000 50000
FRP centrifugal fan Model F4-72 No3.2 No4 No4 No4.5 No4.5 No8 No10 No12 No12
Air quantity (m³/h) 1637 3566 5315 7947 9440 17400 27250 38600 47000
Air pressure (Pa) 1110 1920 1480 2080 1680 1480 1220 1410 1760
Anti-acid water pump Model 50FS-25 50FS-25 50FS-25 50FS-25 50FS-25 50FS-25 50FS-25 50FS-25 50FS-25
Pump head (m) 25 25 25 25 25 35 35 35 35
The initial acid mist concentration HCL mg&sol;m³ < 400
H2SO4 mg&sol;m³ < 300
HNO3 mg&sol;m³ < 1000
Absorption efficiency HCL mg&sol;m³ 91 ~ 99
H2SO4 mg&sol;m³ 92 ~ 98
HNO3 mg&sol;m³ 93 ~ 96
Neutralization solution concentration &percnt; 2 ~ 6
Purification tower resistance &lpar;Pa&rpar; 400
 

Installation and usage notice&colon;
1 The device should be installed on the concrete foundation of more than 100mm above the ground&period; The concrete foundations of pump and fan should be made separately by request&period;
2 Be careful during transportation and installation&period; Don't damage the body and components of the equipemnt&period;
3 When the device is delivered&comma; we will adopt segmental packing and shipping depending on the circumstances&period; We will sent person to the site to install and commiss the device&period;
4 If the device is installed and works outdoors&comma; the user should prevent the pool at the bottom of device from freezing in winter
5 The device has liquid level mark of the pool at the bottom of the device&period; Before use inject the absorbing liquid according to the level mark&period; During use pay attention to add absorbing liquid&period;
6 When using the device&comma; first open the circulating pump for 2-3 minutes&comma; then switch on the blower&period; After use first stop the blower for 1-2 minutes&comma; then stop the circulating pump&period;
7 Check acidity of the liquid in the pool at the bottom of the tower and gas purification degree in the exhaust vent periodically&period; If the results can't meet the standards&comma; replace the absorbing solution in the pool
8 Maintain the device every year and a half to two years&period; Check and clean the sprinkler and packing&period;