TitleProduct

Gas Chromatography for Ethanol in Blood/Laboratory Instrument/Lab Machine

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-06 13:10

  • Browse the number:

    248

Send an inquiries

Company Profile

Nanjing Kejie Analytical Instrument Co., Ltd.

By certification [File Integrity]

Contact:Mr. Chess(Mr.)  

Email:

Telephone:

Phone:

Area:Jiangsu

Address:Jiangsu

Website: http://kojtech.sdshuangyun.com/

PRODUCT DETAILS

New Ethanol in Blood-Analytical Instrument-Gas Chromatography

·Product Description
GC6891N is a laboratory high-end GC of new generation,which is produced according to the international standards. Based on the most advanced international technical area and application experience, its features, reliability and sensitive application are in the world high level.

·Product Features
1. Injector flow, column carrier flow, detector gas flow are controlled by EPC.
1.1 Micro-channel gas integrated board
1.2 Imported micro-ratio and flow/pressure sensor
1.3 Temperature self-compensation to ensure the accurate flow, its pressure controlling can precise to 0.01Psi.
2. Industry-leading detector design.
2.1 All the detectors with high-precision electronic flow/pressure control.
2.2 It can be matched with packed column and capillary column.
2.3 The amplified board after special ceramics treatment can keep stable in wet season.
3. It is safe and reliable with the functions of self-ignition and hydrogen leakage self-protection.  
4. Accurate tracking design for furnace temperature.
 5. Accurate programmed heating control for the furnace temperature.
5.1 Inside temperature controlling precision: <0.01
5.2 Temperature between inside points: ≤1ºC
5.3 Quick heating and cooling, the max programmed heating speed: 120ºC/min, balance time: 10 sec, cooling time: 300ºC-50ºC for 6 minutes.
5.4 The temperature precision is absolutely controlled(compared with the real temperature, the difference is less than 0.3ºC).
6. The achievement of gas circuit cutting technology 
6.1 Complex samples separation can be analyzed by multidimensional chromatograph.
6.2 It saves the analysis time and period by blowback function of the chromatograph column.
7. Chromatograph columns can be heated individually, and the using temperature can be set according to the different columns, so that make every column separately. 
8. GC6891N adopts the advanced power distribution management shunt. One 3000-watt UPS can provide stable working power for 10 sets of GC with the normal power of 2250w/set.
9. GC6891N adopts the imported valve configuration system, which can carry 8 valves (4-way valve, 6-way valve, 10-way valve or liquid sampling valve) to automatically control and operate by sequence.
10. GC6891N uses 8-digit auto-injectors (you can choose Agilent 7683/7693 liquid auto-injector). 
 
·Technical Parameter
Column oven
Furnace dimensions 28 x 30 x 18cm
Temperature controlling rang Higher than the room temperature of 5ºC-450ºC, liquid nitrogen cold trap: -80ºC-400ºC,dry ice cold trap:-55ºC to 400ºC
Temperature setting precision 0.1ºC
Max programmed heating speed 120ºC/min
The longest method run time 999.99 min
The highest step of program 7 steps
Programmed heating rate 0.1-120ºC/min(increment of 0.1ºC)
Column loss can be compensated (dual channel column)
Heating area
Six individual controlling heating areas (do not content furnace temperature control, two injectors, two detectors and two auxiliary heating areas ).
The maximum using temperature in auxiliary heating areas 300ºC
Detectors
FID
Maximum using temperature 450ºC
Minimum LOD: ≤2.5pgC/s[n-C16]
Linear dynamic range 107(±10%)
Data collection frequency Max 100 Hz
Adapted to packed columns and capillary columns
TCD
Maximum using temperature 400ºC
Minimum LOD <400 pgC3H8/ml(He)
Linear dynamic range 105(±5%)
Data collection frequency Max 100 Hz
The design of monofilament TCD and micro-ECD, adapted to packed columns and capillary columns
FPD
Maximum using temperature 250ºC
Minimum LOD <4 pg S/sec,<1 pg P/sec
Linear dynamic range >103S,>104P
Optional 105gS/gC,106gP/gC
Adapted to packed columns and capillary columns
ECD
Maximum using temperature 400ºC
Type of gas compensation detector 5% methane/argon/nitrogen
Minimum LOD <0.01 Pg/sec lindane
Linear dynamic range >5 x 105
Data collection frequency Maximum 100 Hz
Radioactive source <12 mCi 63Ni
Adapted to packed columns and capillary columns
NPD
Maximum using temperature 450ºC
Minimum LOD <0.2 pg N/sec,<0.2 pg P/sec
Minimum LOQ <3 pg C/sec
Linear dynamic range 105 N,105 P
Adapted to packed columns and capillary columns


·Application fields
GC6891N is widely used for the analysis of oil extraction and refining, petrochemical, fine chemical, food safety, environmental protection, electronic high-purity gas industry, scientific research institutes, QC, safety supervision, public security forensic and national security and so on.
Column oven
Furnace dimensions 28 x 30 x 18cm
Temperature range Room temperature +5~420ºC
Temperature setting 1˚C, programmed heating rate 0.1˚C
Maximum heating speed 120ºC/min
Temperature stability it will be 0.01˚C, when the environmental temperature changes 1˚C
Programmed heating 7steps
Programmed heating rate 0.1-120ºC/min(increment of 0.1ºC)
Column loss can be compensated (dual channel column)
FID
Maximum operating temperature 400ºC
LOD ≤5 x 10-12g/s[n-C16]
Drift ≤5 x 10-13A/min
Noise ≤2 x 10-13A
Linear dynamic range ≥107
TCD
Maximum operating temperature 400ºC
Sensitivity ≥10000mv.mL/mg[n-C16]
Drift ≤100μV/30min
Noise ≤20μA
Linear dynamic range ≥105
It is widely used in the fields of petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research and QC.
·detail pictures



·Packing&Shipping
1. Standard export wooden case with high quality cushioning material ensure the item arrive customer in good condition.
2. Carefully check every packing detail before delivery to avoid any troubles during the transportation.
3. Appointed logistics company could be used according to customers demands.
4. Do our best to make sure customer can get their goods in time


·About Kejie Group
Nanjing Kejie Group have one researching institution and four professional production bases,which is a leading manufacturer in R&D, manufacturing and sales of gas chromatography, high efficient liquid chromatography, atomic absorption spectrometer, atomic fluorescence, UV visible spectrophotometer, headspace injector and other analytical instruments and related products. 
 

·Our Service
Our commitment to you doesn't end when your equipment is shipped-It begins.
1. One years'warranty supported by product experts
2. AMC,post warranty,24H/7D response
3. Lifetime's spare parts supply for our products
4. Long term distribution partners worldwide ensure individual on-site customer consultation and service.

·Contact Information
Address:
2nd floor, A1 building, Nanjing University of Sci&Tech,
No.129-3 Guanghua Road, Nanjing City,
Jiangsu Province, China
Postal Code: 210014
Sales Contact
Tel: 0731-84139055
Cell: +86 15211154681
FAX: 0731-89833299
 
Please feel free to submit your inquiry information to us.We will contact with you as soon as possible.
·FAQ
Q1: Are you the factory?
A1: Of course we are,we have one Researching Institution and four Professional Production Bases

Q2:What's the warranty period? How do you provide this?
A2:Two years (24 month).
We have very strict inspection, the instruments which you received are high-quality and reliable.
If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.
If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.
 
Q3:What's the production time?
A3:Usually 20 days for production, some equipments need extra time to debug.
 
Q4:What's the Delivery method ?
A4:Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safety packing)
 
Q5:What's the delivery time?
A5:According to different method and country , express will be 6~15 days
 
Q6:How to install and operate?
A6:According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)
 
Q7:What's the payment term?
A7:Usually we do 50%TT deposit ,50%TT balance before shipping.Western Union, are acceptable.